§ 153.05 SUBSTANTIVE VARIATION.
   The requirement of a safety ledge contained in subsection (3) of Section H, “Detention Basin Design Requirements,” as contained in the County Storm Water Policy is replaced by the following:
“(3) A safety ledge ten (10) feet in width is required and must be installed in all ponds from the water’s edge at a depth of one (1) foot. In addition, a maintenance ledge twelve (12) to eighteen (18) inches above the permanent water line shall be provided. The slope between the two ledges shall be 10:1 and be covered with a material such as stone or rip-rap which will prevent erosion due to wave action.”
(Prior Code, § 152.05) (Ord. 2002-140, passed 5-14-2002)