§ 152.42 ELECTRICAL AND TELEVISION SERVICE; INDIVIDUAL ELECTRICAL CONNECTIONS.
   (A)   For individual electrical connections, the following standards shall be required.
      (1)   Every space shall be served and metered by the private or public utility in the same manner as for a single-family residential lot with an underground service line and shall be provided with approved disconnecting device and over current protective equipment. The minimum service per outlet should be 120/240 volts AC, 50 amperes.
      (2)   Outlets, receptacles or pressure connectors shall be housed in an Underwriters’ Laboratory approved weather-proof outlet box and shall be located not more than 25 feet from the over current protective device in the mobile home. Three pole and four wire, grounding type outlets shall be used.
      (3)   The mobile home shall be connected to the outlet box by an Underwriters’ Laboratory approved type of flexible supply cord with a male attachment plug or pressure connectors. If the distance from the receptacle to the mobile home exceeds three feet, the cord shall be installed underground.
   (B)   All exposed noncurrent-carrying metal parts of mobile homes and all other equipment shall be grounded by means of an approved grounding conductor with branch circuit conductors. The neutral conductor shall not be used as an equipment ground for mobile homes or other equipment and the grounding conductor shall be attached to a permanent ground in an approved manner.
(Code 2019, § 12-22) (Ord. passed 5-13-1974) Penalty, see § 10.99