9-1-4: AMENDMENTS TO INTERNATIONAL RESIDENTIAL CODE:
IRC Section R101.1. IRC section R101.1 (Title) is amended by the addition of the term "town of Morrison" where indicated.
IRC Section R102.7. IRC section R102.7 (Existing Structures) is amended by deleting the words "international property maintenance code."
IRC Section R105.1. IRC section R105.1 (Required) is amended by replacing the words "building official" with "town."
IRC Section R108.5. IRC section R108.5 (Refunds) is amended by deleting the section in its entirety and replacing the section with the following:
The town may authorize refunding of any fee paid hereunder which was erroneously paid or collected. The town may authorize refunding of not more than 75 percent (75%) of the permit fee paid when no work has been done under a permit issued in accordance with this code. The town may authorize refunding of not more than 75 percent (75%) of the plan review fee paid when an application for a permit for which a plan review fee has been paid is withdrawn or cancelled before any plan reviewing is done. The town shall not authorize refunding of any fee paid except on written application filed by the original permittee not later than 180 days after the date of fee payment.
IRC Section R109.1.5. IRC section R109.1.5 (Other Inspections) is amended by the addition of new subsections as follows:
IRC Section R112. IRC section R112 (Board Of Appeals) is deleted.
IRC Section R202. IRC section R202 (Definitions) is amended by addition of the following:
"Sleeping Room" (Bedroom) Any enclosed habitable space within a dwelling unit, which complies with the minimum room dimension requirements of IRC sections R304 and R305 and contains a closet, an area that is useable as a closet, or an area that is readily convertible for use as a closet. Living rooms, family rooms and other similar habitable areas that are so situated and designed so as to clearly indicate these intended uses, shall not be interpreted as sleeping rooms.
IRC Table R301.2(1). IRC table R301.2(1) is filled to provide the following:
TABLE R301.2(1)
CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
 
Ground Snow Load
Wind Speed (mph)
Seismic Design Category
Subject To Damage From
Winter Design Temp
Weathering
Frost Line Depth
Termite
37psf
130
B
Severe
36 in.
Slight to moderate
1
 
 
Ice Shield Underlayment Required
Flood Hazard
Air Freezing Index
Mean Annual Temp
Required
05/06/2003
1000
45°F
 
IRC Section 313.2. One- and two-family dwellings automatic fire systems. Delete this section in its entirety.
IRC Section G2415.9. IRC section G2415.9 (Minimum Burial Depth) is amended by the addition of the following: All plastic fuel gas piping shall be installed a minimum of 18 inches (457 mm) below grade.
IRC Section G2415.9.1. IRC section G2415.9.1 (Individual Outside Appliances) is deleted in its entirety.
IRC Section G2417.4.1. IRC section G2417.4.1 (Test Pressure) is amended by changing "3 psig" to "10 psig."
IRC Section P2603.6.1. IRC section P2603.6.1 (Sewer Depth) is amended by filling in both areas where indicated to read "12 inches (305 mm)."
(Ord. 357, 10-21-2008; amd. Ord. 477, 8-6-2019)