The connection of the building sewer into the public sewer shall be made at the “Y” branch or “T” connection, if such branch is available at a suitable location. If the public sewer does not have a properly located “Y” branch or “T” connection, the owner shall, at his or her expense, install an approved tapping saddle in the public sewer at the location specified by the Sewer Inspector. The tapping saddle shall be installed in a neatly tapped hole cut into the public sewer; said connection between the tapping saddle and public sewer shall be secured by the use of epoxy compound or other approved sealant. The centerline of the building sewer at the tapping saddle shall be at or above the centerline of the public sewer but not in the top. A smooth, neat joint shall be made and the connection made secure and water-tight. Special fittings may be used for the connection only when approved by the Sewer Inspector.
(Ord. 17-1989, passed 12-5-1989)