909.06 CONFORMANCE WITH REGULATIONS.
   All public sidewalks as constructed in the Village shall be constructed according to the width, line and grade established by the Street Superintendent and the Village Administrator, and shall be either:
   (a)   One course concrete mixed in the proportion of 1:2:3 - one part cement, two parts sand and three parts stone, or a 6 bag mix, and shall not be less than four (4) inches thick.
   (b)   One course concrete and one course paving brick. The concrete course shall be described in subsection (a). A one (1) inch sand or wet mortar layer is to be placed between the course of concrete and brick. A minimum four (4) inch wide concrete curb is to border the brick course on both sides and be tied into the concrete course using No. 6 dowels, five (5) inches long and having a two (2) foot center. The concrete curb shall also have No. 6 reinforcing bars placed approximately in the center and running parallel to the curbing.
   (c)   Where portions of the sidewalk for either subsections (a) or (b) above are used for driveways, the concrete course shall not be less than six (6) inches in thickness. Where fill is required material shall be cinders, sand or screening.
      (Ord. 02-11. Passed 3-19-02.)