§ 154.110 AREA/CONSTRUCTION REGULATIONS.
   (A)   Minimum lot area, maximum building height, maximum lot coverage, and minimum yard requirements shall be regulated in accordance with the following tables.
Table 17.09.06.1
Minimum Lot Area
Minimum Lot Width
(in feet)
Maximum Height
(in feet)
Maximum Percent Lot Coverage
Table 17.09.06.1
Minimum Lot Area
Minimum Lot Width
(in feet)
Maximum Height
(in feet)
Maximum Percent Lot Coverage
Single-family residential
5,750 square feet
50
35
35%
2 dwelling units (a)
5,000 square feet/dwelling unit
85
35
40%
3 to 8 dwelling units (a)
10,000 plus 1,000 square feet for each dwelling unit over 4
100
45
40%
Assisted living, nursing and rest homes, and the like
2,000 square feet/dwelling unit
60
35
40%
Churches, synagogues, chapels, and other similar places of worship
87,120 square feet (2 acres)
75
35*
30%
Notes:
a: Maximum height for steeples and towers shall be 75 feet
b: Construction between 35 feet and 45 feet is allowed only if fire suppression sprinklers are installed and maintained with the most recently published version of the International Fire Code
 
   (B)   Where individually owned, attached, single-family units (e.g., condominium, townhouse, duplex, and the like) are constructed, minimum lot area, width, and coverage are calculated on the basis of the lot upon which the shared structure is constructed.
Table 17.09.06.2
Minimum Front Yard (in feet)
Minimum Rear Yard (in feet)
Minimum Side Yard (in feet)
Table 17.09.06.2
Minimum Front Yard (in feet)
Minimum Rear Yard (in feet)
Minimum Side Yard (in feet)
Primary
Secondary (a)
Party Wall Side
Non-Party Wall Side
Symbol
Single-family residential
25
12.5
25
8
2 dwelling units
25
12.5
10
0
8
3 or more dwelling units
25
12.5
25
0
10
Hospitals, convalescent and nursing homes, supervised care facilities and congregate housing
50
30
30
Note:
a: See Chapter 17.27.5 for lots created before 1968.
 
(Ord. 842, passed 3-14-2022; Ord. 848, passed 7-7-2023)