The description of an unsafe building contained in I.C. 36-7-9-4 is hereby supplemented to provide minimum standards for building conditions or maintenance in the town, by adding the following: any building or structure which has any or all of the conditions or defects hereinafter described shall be deemed to be an unsafe building; provided that, the conditions or defects exist to the extent that life, health, property or safety of the public or its occupants are endangered:
(A) Whenever any door, aisle, passageway or other means of exit is not of sufficient width or size or is not so arranged as to provide safe and adequate means of exit in case of fire or panic;
(B) Whenever the stress in any materials, member or portion thereof, due to all dead and live loads, is more than one times the working stress or stresses approved for new buildings of similar structure, purpose or location;
(C) Whenever any portion thereof has been damaged by fire, earthquake, wind, flood or by any other cause, to an extent that the structural strength or stability thereof is materially less than it was before the catastrophe and is less than the approved minimum requirements for new buildings of similar structure, purpose or location;
(D) Whenever any portion, member or appurtenance thereof is likely to fail, become detached or dislodged or to collapse and thereby injure persons or damage property;
(E) Whenever any portion of a building or any member, appurtenance or ornamentation on the exterior thereof is not of sufficient strength or stability or is not so anchored, attached or fastened in place so as to be capable of resisting a wind pressure of one-half of that specified for new buildings of similar structure, purpose or location without exceeding the working stresses approved for the building; or whenever any portion thereof has cracked, warped, buckled or settled to an extent that walls or other structural portions have materially less resistance to winds or earthquakes than is approved in the case of similar new construction;
(F) Whenever the building or structure, or any portion thereof, because of dilapidation, deterioration or decay; faulty construction; the removal, movement or instability of any portion of the ground necessary for the purpose of supporting the building; the deterioration, decay or inadequacy of its foundation; or any other cause, is likely to partially or completely collapse;
(G) Whenever the building or structure, or any portion thereof, is manifestly unsafe for the purpose for which it is being used;
(H) Whenever the exterior walls or other vertical structural members list, lean or buckle to an extent that a plumb line passing through the center of gravity does not fall inside the middle one-third of the footer; this item shall not be the sole criteria for evaluating non-inhabited accessory structures;
(I) Whenever the building or structure, exclusive of the foundation, shows 33% or more damage or deterioration of its supporting member or members, or 50% damage or deterioration of its non-supporting members, enclosing or outside walls or coverings;
(J) Whenever the building or structure has been so damaged by fire, wind, earthquake or flood, or has become so dilapidated or deteriorated so as to become an attractive nuisance to children, or freely accessible to persons for the purpose of committing unlawful acts;
(K) Whenever any building or structure that has been constructed, exists or is maintained in violation of any specific requirement or prohibition applicable to the building or structure provided by the building regulations of the County Building Department or of any law or ordinance of the state or town relating to the condition, location or structure of buildings;
(L) Whenever any building or structure which, whether or not erected in accordance with all applicable laws and ordinances, has in any non- supporting part, member or portion less than 66% of the strength, fire resisting qualities or characteristics, or weather-resisting qualities or characteristics approved by law in the case of a newly constructed building of like area, height and occupancy in the same location;
(M) Whenever a building or structure, used or intended to be used for residential or nonresidential purposes because of inadequate maintenance, dilapidation, decay, damage, faulty construction or arrangements, inadequate light, air or sanitation facilities or otherwise is determined by the Council or its designee to be unfit for human occupancy, to be insanitary or in a condition that is likely to cause sickness or disease;
(N) Whenever any building or structure, because of obsolescence, dilapidated condition, deterioration, damage, inadequate exits, lack of sufficient fire- resistive construction, faulty electric wiring, gas connection or heating apparatus or other cause is determined by the Council or its designee to be a fire hazard; or
(O) Whenever any portion of a building or structure remains on a site after the demolition or destruction of the building or structure or whenever any building or structure is abandoned for a period in excess of six months so as to constitute the building or portion thereof an attractive nuisance or hazard to the public.
(Ord. 3-13-00-3, passed 3-13-2000)