4-17-6: FACILITIES REQUIREMENTS:
No license to conduct a massage establishment shall be issued unless an inspection by the inspector reveals that the establishment complies with each of the following minimum requirements:
   A.   Construction of rooms used for toilets, tubs, steam baths, and showers shall be made waterproof with approved waterproofed materials and shall be installed in accordance with the Milan building code. Plumbing fixtures shall be installed in accordance with the Milan plumbing regulations.
      1.   For toilet rooms, toilet room vestibules and rooms containing bathtubs, there shall be a waterproof floor covering, which will be carried up all walls to a height of at least six inches (6"). Floor shall be covered up on base with at least three-fourths inch (3/4") cover. The walls of all toilet rooms and rooms containing bathtubs shall be finished to a height of six feet (6') with a smooth, nonabsorbent finish surface of Keene cement, tile, or similar material.
      2.   Steam rooms and shower compartments shall have waterproof floors, walls and ceilings approved by the inspector.
      3.   Floors of wet and dry heat rooms shall be adequately pitched to one or more floor drains properly connected to the sewer. (Exception: Dry heat rooms with wooden floors need not be provided with pitched floors and floor drains.)
      4.   A source of hot water must be available within the immediate vicinity of dry and wet heat rooms to facilitate cleaning.
   B.   Toilet facilities shall be provided in convenient locations. When five (5) or more employees and patrons of different sexes are on the premises at the same time, separate toilet facilities shall be provided. A single water closet per sex shall be provided for each twenty (20) or more employees or patrons of the sex on the premises at any one time. Urinals may be substituted for water closets after one water closet has been provided. All toilet rooms shall be equipped with self-closing doors opening in the direction of the ingress to the toilet rooms. Toilets shall be designated as to the sex accommodated therein.
   C.   Lavatories or washbasins provided with hot and cold running water shall be installed in either the toilet room or the vestibule. Lavatories or washbasins shall be provided with soap in a dispenser and with sanitary towels.
   D.   All portions of massage establishments and baths shall be provided with adequate light and ventilation by means of windows or skylights with an area not less than one-eighth (1/8) of the total floor area, or shall be provided with approved artificial light and a mechanical operating ventilating system. When windows or skylights are used for ventilation, at least one-half (1/2) of the total required window area shall be operable. To allow for adequate ventilation, cubicles, rooms and areas provided for patrons' use not served directly by a required window skylight, or mechanical system of ventilation shall be constructed so that the height of partitions does not exceed seventy five percent (75%) of the floor to ceiling height of the area in which they are located.
   E.   All electrical equipment shall be installed in accordance with the requirements of the Milan electrical regulations. (Ord. 1584, 7-15-2013)