1195.01 CONSTRUCTION PLAN; PROFILE; CROSS SECTIONS.
   Prior to the submission of the plat for approval by the Planning Commission, the owner shall submit a complete construction plan and profile to the Village Engineer or in absence of such Village Engineer, the County and Sanitary Engineer, at a scale of not smaller than one inch to forty feet horizontally and one inch to four feet vertically, in material suitable to the village engineer twenty-four inches by thirty-six inches, showing the proposed grading, drainage, paving, sanitary sewers and water lines within the subdivision. Such plan shall be accompanied by cross sections of the proposed streets, at a scale of not smaller than one inch to ten feet, in material suitable to the County and Sanitary Engineers, twenty-four by thirty-six inches. Such cross sections shall show the extreme width limits of the streets. Such cross sections shall show the contour of the existing ground and the contour of the proposed pavement, walks and finish grading, and the relative location of the proposed sewers and water lines. Such plan shall include the following information:
   (a)   Name of proposed subdivision.
   (b)   North arrow, scale, date and benchmark with elevation above sea level on each street.
   (c)   Typical cross section of the proposed street right-of-way showing in detail the pavement design, sidewalks and the relative location of the proposed water line, sanitary sewer, storm sewer and gas line.
(Ord. 871-6-91. Passed 6-25-91.)