Note: When circumstances exist which make impractical full compliance with the requirements of the Ordinance, an applicant may request a variance. Each variance request is reviewed in conjunction with the specific on-site conditions. It should not be assumed that a variance will automatically be granted. The following table provides general guidelines for variances which may be considered for private sewage disposal systems for new construction:
Septic System Component | Minimum Separation with a Variation Granted | ||||
Water Line Under Pressure | Dwelling | Property Line | Accessory Structure, Above Ground Swimming Pool, | Criteria |
Septic System Component | Minimum Separation with a Variation Granted | ||||
Water Line Under Pressure | Dwelling | Property Line | Accessory Structure, Above Ground Swimming Pool, | Criteria | |
Building Sewer | See Footnote 3 in Table IV | N/A | N/A | 5 feet | Amount of area available, location of adjacent dwellings, water wells, etc. |
Septic Tank | 5 feet | 2 1/2 feet | 2 1/2 feet | 2 1/2 feet | Amount of area available, location of adjacent dwellings, water wells, etc. |
Aerobic Treatment Unit | 5 feet | 2 1/2 feet | 2 1/2 feet | 2 1/2 feet | Amount of area available, location of adjacent dwellings, water wells, etc. |
Distribution or Drop Box | No variance | 10 feet 1 | 2 1/2 feet | 5 feet | Amount of area available, soil permeability, site topography, locations of adjacent dwellings, water wells, etc. |
Subsurface Seepage System | 12 1/2 feet | 10 feet 1 | 2 1/2 feet | 5 feet | Amount of area available, soil permeability, site topography, locations of adjacent dwellings, water wells, etc. |
1. Typically granted in moderate soil permeabilities where space is limited. Typically not granted in moderately rapid or rapid soil permeabilities, or when the septic system is upgradient of the dwelling. | |||||
(Ord. O-201711-51-031, passed 11-14-2017)