TABLE IV: MINIMUM SEPARATIONS1.
Table IV: Minimum Separations 1
Component
Part of System
I
Well or Suction Line from Pump to Well
II
Water Supply Line3 Pressure
III
Lake, Stream, Retention Pond, or Other Body of Water
IV
Dwelling with or without attached garage
V
Property Line
VI
Field Drain Line/ Curtain Drain
VII
Inground Swimming Pool
VIII
Accessory Structure or Above Ground Swimming Pool
IX
Sealed Wells
Table IV: Minimum Separations 1
Component
Part of System
I
Well or Suction Line from Pump to Well
II
Water Supply Line3 Pressure
III
Lake, Stream, Retention Pond, or Other Body of Water
IV
Dwelling with or without attached garage
V
Property Line
VI
Field Drain Line/ Curtain Drain
VII
Inground Swimming Pool
VIII
Accessory Structure or Above Ground Swimming Pool
IX
Sealed Wells
Building Sewer 2
50
10
25
10
25
10
10
Septic Tank or Aerobic Treatment Plant
50
-+10
25
5
5
10
25
5
10
Dist. Or Drop Box
75
10
50
20
5
20
25
10
25
Subsurface Seepage System
75
25
50
20
5
20
25
10
25
Sand Filter
75
25
50
20
5
20
25
10
25
Privy or chemical toilet
75
25
25
20
5
10
25
10
NA
Special Waste Holding Tank
50 4
10
25
5
5
10
25
5
10
Subsurface Seepage System Classified as a Class V Injection Well
200
25
50
20
5
20
25
10
25
Note: All measurements are in feet.
1. These distances have been determined for use in clay and loam soils only. The minimum distances required for use in sand or other types of soil shall be determined for the proposed private sewage disposal system and approved by this Department. Such approval will be given where the Department determines that the soil will provide treatment of the sewage.
2. The building sewer may be located to within 10 feet of a well or suction line from the pump to the well when cast iron pipe with mechanical joints or Schedule 40 PVC pipe with water-tight joints is used for the building sewer.
3. See Section 310. Septic system components shall maintain a minimum separation of 25 feet from drainage or stormwater detention easements for surface drainage or water collection or 15 feet from a conduit or pipe.
4. The minimum separation distance shall be 200 feet if the special waste holding tank meets the criteria of a potential secondary source as defined.
 
(Ord. O-201711-51-031, passed 11-14-2017)