9.4.073: SITE REQUIREMENTS:
The following shall be considered the minimum site requirements for a new mobile home park or the expansion of an existing mobile home park:
   (A)   Accessways: At least two (2) accessways shall connect each mobile home space to public right of way and shall be a minimum of thirty four feet (34') in width. Where the entrance accessway is divided by a median planting strip, the minimum width shall be fifty feet (50') and each side shall then be one way.
   (B)   Recreation Area: A minimum of two hundred (200) square feet of recreation area shall be provided for each mobile home space. The recreation area may be in one or more locations in the park. At least one recreation area shall have a minimum size of five hundred (500) square feet and be of a shape that will make it usable for its intended purpose.
   (C)   Electricity:
      1.   Installation of meter bases to serve each mobile home shall comply with provisions of the state electrical code.
      2.   An electrical permit must be obtained from the state for inspection of any placement or replacement of mobile homes in the park.
   (D)   Sewage Disposal:
      1.   All plumbing in the mobile home park must connect to the public sewer system and shall comply with the most current version of the international plumbing code.
      2.   Each mobile home space shall be provided with at least a three inch (3") sewer connection. Said connection shall be provided with suitable fittings, so that a watertight connection can be made between the mobile home drain and sewer connection. Such individual mobile home connections shall be so constructed that they can be closed when not linked to a mobile home, and shall be trapped in such a manner as to maintain them in an odor free condition.
      3.   Sewer connection fees for each mobile home space will be that amount established by resolution of the city council.
      4.   A plumbing permit must be obtained from the state for inspection of the placement or replacement of each mobile home in the park.
   (E)   Water Supply: An accessible, adequate, safe and potable supply of water shall be furnished in each mobile home park, capable of furnishing a minimum of five (5) gallons per minute per mobile home space. All water piping shall be constructed and maintained in accordance with state of Idaho regulations for public drinking water systems.
      1.   Individual water service connections which are provided for direct use by mobile homes shall be so constructed that they will not be damaged by the parking of such homes. The mobile home park water system shall be adequate to provide thirty five (35) pounds per square inch of pressure at all mobile home connections.
      2.   Fees for connecting to the city water system will be that amount established by resolution of the city council.
   (F)   Hydrants: Hydrants will be installed in accordance with the international fire code. An adequate water supply of at least three hundred (300) gallons per minute shall be provided.
   (G)   Building Permit: Construction or alteration of a mobile home park requires a permit from the building department.
   (H)   Setbacks: Setbacks from adjacent developments or properties shall be in accordance with the setback requirements of those properties. (Ord. 822, 2-23-2006, eff. 8-16-2006)