§ 96.12 INLETS.
   (A)   Private residential swimming pool water recirculation system inlet shall be located so as to produce so far as possible uniform circulation of water throughout the pool without the existence of dead spots and to carry pool bottom deposits to the outlets and shall discharge at a minimum depth of 10 inches below the pool overflow level.
   (B)   Pools shall be equipped with suitable facilities for adding make-up water as needed. There shall be no physical connection between the water supply line and the pool system. If a hose connection from a sill cock or other plumbing fixture is to be used for supplying make-up water, then an approved vacuum breaker shall be installed between the sill cock or control valve at the fixture and the hose connection. The vacuum breaker shall be installed at a height not less than 7 feet 6 inches above the floor, platform or ground upon which a person would stand when operating the sill cock or control valve.
   (C)   The system supplying recirculated water and make-up water to the pool shall be constructed in conformance with Village ordinances.
(1997 Code, § 28.12) (Ord. 69-14, passed 6-8-1967)