§ 150.031 ADDITIONS, INSERTIONS, DELETIONS AND CHANGES.
   The following sections are hereby revised; the following sections or subsections are not adopted and specifically excluded in their entirety, unless otherwise specified.
   (A)   Section 890.320. Delete subpart (1) Plastic Pipe joints, items number 1 and 2.
   (B)   Section 890. Appendix A Table A, Approved Building Drainage/Vent pipe. Delete item 12 Polyvinyl Chloride (PVC) Pipe with Cellular Core and footnote 4.
   (C)   Section 890 Appendix A, Table A. Approved materials for Water Service Pipe. Delete Items 1, 4, 7, 8, 9, 10, 11, and 12.
   (D)   Section 890, Appendix A, Table A. Approved Materials for Water Distribution Pipe, Items 2, 5, 7, 8, and 9.
   (E)   Section 890.210 Materials. Shall be amended to add at the end of section 890.210 the following:
      j.   All copper water tubing, when installed underground shall be a minimum type K, and when copper tubing in used above grade shall be a minimum Type L copper. All water service lines shall be sized per 890 Table N, Water Supply Fixture Unit, with service pipe no less than 1 inch in size.
   (F)   Section 890.330 Special joints (c) Slip joint. Shall be amended to delete the reference to CPVC potable water applications.
   (G)   Section 890.340 Use of joints. Shall be amended to add the following language to the end of item (I) Copper Water Tube.
      (1)   Flared joint adapter shall be required at all water service supply lines two (2) inches or less with full port ball valve upstream of the water meter.
      (2)   Soldered and or braided fittings shall not be installed below grade.
   (H)   Section 890.420 pipe cleanouts. Add item number 6 under subsection (a) to read as follows: On multiple unit construction a cleanout shall be extended to the exterior of the foundation at the end of the building drain runes).
   (I)   890.1360 Sanitary waste below sewer. b) Shall be amended by adding the following at the end of the subsection:
      No sump or ejector basin shall be less than 30 inches deep with a minimum 14 inch sump below inlet pipe invertor or a design specified by manufacture and approved by the Village of Matteson Plumbing Inspector.
(2000 Code, § 150.027) (Ord. 1650, passed 1-6-1997; Ord. 1931, passed 10-6-2003; Ord. 2023, passed 4-18-2005; Ord. 4296, passed 2-1-2016; Ord. 4476, passed 10-18-2021)