925.08 COMPLIANCE WITH STATE HEALTH REGULATIONS.
   The type, capacities, location, and layout of a private sewage disposal system shall comply with all recommendations of the City Health Department. No permit shall be issued for any private sewage disposal system employing subsurface soil absorption facilities where: the total area of the lot is less than 20,000 square feet, the area of suitable leaching field is less than 11,000 square feet, the percolation rate of the leaching field soil is less than one inch per hour. No private sewage disposal system shall be permitted in Canfield soils where the area of the lot is less than five acres. No septic tank or cesspool shall be permitted to discharge to any public sewer or natural outlet.
(Ord. 69-1991. Passed 4-15-91.)