1143.07 FINAL PLAT DATA .
   The final plat shall be a scaled drawing and the following requirements and identifying information shall be observed.
(a)    Name of subdivision.
(b)    Location by township, section and range, or by other legal description and vicinity sketch.
(c)    Name of owners and registered surveyor.
(d)    Scale shall be not less than one inch equals fifty feet as indicated on the plat and shown graphically.
(e)    Date.
(f)   Northpoint.
(g)    Boundary of plat shown with a double line and based on an accurate traverse, with angular bearings and lineal dimensions (feet, tenths, and hundreds) with an accuracy of one to 10,000.
(h)    Exact locations, width and name of all streets within and adjoining the plat, and the exact location and widths of all alleys and crosswalks. The name of a street shall not duplicate any existing street in the City. Proposed street names shall be checked with the City Engineer.
(i)    True angles and distances to the nearest established street lines, property lines, or official monuments, where practical shall be accurately described on the plat.
(j)    Municipal township, county or section lines shall be accurately tied to the lines of the subdivision by distance and angles.
(k)    Radii, internal angles, points of curvature, tangent bearings, lengths of all tangents and curve data along the center lines of all streets shall be shown and shall have an accuracy of one in 10,000 in their relations with outside boundary.
(l)    All easements for right-of-way provided for public services, utilities, storm water and ditch drainage and maintenance shall be dedicated to the City or appropriate political subdivision as follows:
   An easement is hereby dedicated to the City of Marietta, Ohio, or an appropriate political subdivision, to locate, construct, operate and maintain or authorize the location, construction, operation, maintenance, and use of conduits for all and any purpose water, gas, electric, telephone, sanitary sewer, storm sewer and drainage, poles and wires, or all or any of them over, under and along the strips marked "Utility Easements".
(m)    All lots shall be numbered and all lot line dimensions shown with accurate dimensions in feet and hundredths.
(n)    Monuments and iron pins to be placed as follows:
(1)    Monuments shall be constructed out of concrete four inches in diameter and thirty inches long with an iron pin cast in center. They shall be located at each change in direction of the boundary and at strategic points inside the subdivision or as directed by the City Engineer.
(2)    Iron pins (1" in diameter and 30" long) shall be placed at the corners of all lots not covered in subsection (n)(1) hereof.
(3)    When streets are completed, reference points shall be placed on centerline at each street intersection and at the points of all curves.
(o)    Accurate outlines and measurements of any areas to be dedicated for public use with the purpose indicated thereon.
(p)    Building setback lines shall be accurately shown with dimensions established as follows:
"Building lines or setback lines are hereby established as shown on the accompanying plat and no building or portion thereof shall be built between this line and the street line".
(q)    Certification by registered surveyor to the effect that the plat represents a survey made by him and that the monuments and iron pins shown thereon exist as located at the time of completion.
(r)    Notarized certification, by the owner or owners, of the adoption of the plat and the dedication of streets, easements, and other areas as follows: "Streets (parks, schools, etc. ) shown on this plat and not heretofore dedicated to public use are hereby so dedicated to the public use forever. "
(s)    Proper format for the approval statement of the Planning Commission and acceptance of Council and the City Engineer.
(t)    The original tracing shall be drawn with water proof ink on tracing cloth or linen bearing all signatures and after recording, shall become the property of the City Engineer's Department. Maximum sheet size shall be 24" x 36" with extra sheets as needed. The Washington County Recorder should be contacted as to additional requirements for recording plats.
(u)    The original construction drawing shall be certified by a registered civil engineer and drawn on plan profile cloth, acceptable size 24" x 36" or 22" x 36" and drawn on a twenty feet to an inch scale horizontal and one inch = five feet scale vertical. These tracings shall become the property of the City Engineer's Office. The developer shall be responsible to see that the construction drawings are brought up to date (as built) after construction has been completed.
(v)    Following certificates:
(1)    Certification shall be required showing that the subdivision is in accordance with the desire of the owners, including spouses’ signatures.
(2)    Certification shall be required showing that all required improvements have either been installed and approved by the proper officials or agencies, or that a bond or other surety has been furnished assuring installation and initial maintenance of the required improvements.
(w)    Names of adjacent subdivisions, owners of adjoining parcels of unsubdivided land, and the location of applicable boundary lines.
(x)    All restrictions and covenants the subdivider intends to include in the deed to the lots in the subdivision shall be shown on the plat.
(Ord. 81 (82-83). Passed 12-16-82; Ord. 280(00-01). Passed 12-6-01.)