§ 160.065 CHAPTER 16: DUCT SYSTEMS.
   The following sections of the 2015 International Residential Building Code, Chapter 16: Duct Systems are hereby revised as follows:
   (A)   M1601.1.1 Above-ground duct systems.
      (1)   DELETE: 5. The use of gypsum products to construct return air ducts or plenums is permitted, provided that the air temperature does not exceed 125°F (52°C) and exposed surfaces are not subject to condensation.
      (2)   AMEND: 7. Stud wall cavities and the spaces between solid floor joists to be used as air plenums shall comply with the following conditions:
      (3)   AMEND: 7.1. These cavities or spaces shall not be used as a plenum for supply air or return air.
      (4)   ADD: 7.1.1 Return air must be ducted with metal or flex ducting.
      (5)   ADD: 7.1.2 When return air ducting and electrical wiring, switches or receptacles conflict metal ducting is required.
(Ord. 22-12-01, passed 12-20-2022)