§ 154.082 SANITARY SEWER SYSTEM.
   General. In general, all sites within 500 feet of a public sanitary sewer main shall connect to and utilize the public sanitary sewer system. This requirement may be waived by agreement of both the Village Engineer and Village Planner if a substantial physical obstruction prevents connection without incurring extraordinary costs.
   (A)   No plat of any subdivision shall be approved unless the subdivider provides for construction of a sanitary sewer system adequate to serve the needs of the entire subdivision when the same is fully developed. The location and design of the sanitary sewer system shall be approved by the village, the Illinois Environmental Protection Agency, and the corporate authorities of the sanitary sewer district in which the subdivision is located. This requirement shall not apply to any new subdivision which cannot reasonably be provided with sanitary sewer service.
   (B)   The adequacy of the existing sanitary sewers to which the proposed development is to outlet into must first be determined by the subdivider. If the existing sewers are not adequate, it shall be the subdivider’s responsibility to find an outlet for the sanitary sewers. This work shall be done in cooperation with the Village Engineer. Capacity of sanitary sewers shall be determined utilizing Illinois Environmental Protection Agency regulatory requirements. The peaking factor for all eight inch and ten inch diameter sewers shall be at least 4.0.
   (C)   All permits required must be obtained by the subdivider (i.e. Environmental Protection Agency permit). Permit application forms shall be reviewed and approved by the Village Engineer before being submitted to the Illinois Environmental Protection Agency.
   (D)   All sanitary sewer work shall be performed in accordance with the current Standard Specifications for Water and Sewer Main Construction in Illinois, the regulations of the Illinois Environmental Protection Agency, and the village sewer use ordinance.
   (E)   The sanitary sewer system in each new subdivision shall continue and extend existing, connecting sanitary sewers in adjoining subdivisions.
   (F)   The sanitary sewer system in each new subdivision shall be extended to any property adjacent to the subdivision, except in those instances in which the adjacent property is not and cannot be subdivided in the future.
   (G)   No private sanitary sewers or onsite wastewater disposal systems shall be permitted.
   (H)   Each lot within a new subdivision shall be provided with a service connection to the public sanitary sewer system.
   (I)   All sanitary sewer system facilities shall conform to the requirements of the Village of Mahomet Infrastructure Design Manual.
(Ord. 15-12-01, passed 12-15-2015)