The pavement shall include concrete curbs. If cast-in-place concrete, the curbs shall be six inches wide by eighteen inches deep. If integral concrete curbs are used, the details must be approved by the City Engineer and the Planning Commission. Curb drains of four-inch vitrified sewer pipe, hub and spigot pattern or approved equal shall be constructed at the back of the curb to a depth of twenty-four inches below the top of the curb and backfilled with number 67 washed limestone or approved equal. All curbs shall be constructed in conformity with the most recent edition of State of Ohio Department of Transportation Construction and Material Specifications.
(Ord. 96-61. Passed 4-21-97.)