§ 1480.37 ELECTRICAL SERVICE, OUTLETS AND FIXTURES.
   Every dwelling shall be supplied with adequate electrical service, outlets and fixtures which shall be properly installed and maintained in a safe working condition and connected to an approved source of electric power in an approved manner. The capacity of such services and the number of outlets and fixtures in dwellings shall be as follows.
   (a)   Every habitable room shall contain a minimum of two separate duplex electric convenience outlets. Outlets shall be located in an approved manner so as to provide service to appliances in different parts of the room and shall not serve more than two appliances from any one duplex convenience outlet.
   (b)   Every laundry or utility room shall contain at least one duplex electric convenience outlet and one wall or ceiling-type electric light fixture.
   (c)   Every bathroom, toilet room, hall and furnace room shall contain at least one wall or ceiling-type electric light fixture and every bath shall contain at least one convenience outlet.
   (d)   Where the occupancy or use of a dwelling is increased after the enactment of this Housing Code (Ordinance 11-1977, passed May 16, 1977), electrical service, outlets and fixtures shall be as specified in the Building Code.
(Ord. 11-1977, passed 5-16-1977)