No person shall occupy as owner-occupant, or let to another for occupancy, any dwelling or dwelling unit, for the purpose of living therein, which does not comply with the requirements set forth in divisions (A) through (G) below.
(A) Every habitable room shall have at least one window or skylight facing directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall be 10% of the floor area of such room. Whenever walls or other portions of structures face a window of any such room and such light-obstructing structures are located less than three feet from the window and extend to a level above that of the ceiling of the room, such a window shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight-type window in the top of such room, the total window area of such skylight shall equal at least 15% of the total floor area of such room.
(B) Every habitable room shall have at least one window or skylight which can easily be opened, or such other device as will adequately ventilate the room. The total of openable window area in every habitable room shall be equal to at least 45% of the minimum window area size or minimum skylight-type window size, as required in division (A) above, except where there is supplied some other device affording adequate ventilation and approved by the Health Officer. An approved system of mechanical ventilation or air conditioning may be used in lieu of openable windows. Such system shall provide not less than four air exchanges per hour.
(C) Every bathroom and water closet compartment shall comply with the light and ventilation requirements for habitable rooms contained in divisions (A) and (B) above, except that no window or skylight shall be required in adequately ventilated bathrooms and water closet compartments equipped with a ventilation system which is kept in proper working condition and approved by the Health Officer.
(D) (1) Every habitable room of each dwelling shall contain at least two separate floor- or wall-type electric convenience outlets, or one such convenience outlet and one supplied ceiling-type electric light fixture; and every water closet compartment, bathroom, laundry room, furnace room, and public hall shall contain at least one supplied ceiling- or wall-type electric light fixture.
(2) Every such outlet and fixture shall be properly installed, shall be maintained in good and safe working condition, and shall be connected to the source of electric power in a safe manner.
(E) Every dwelling shall have heating facilities which are properly installed, are maintained in safe and good working condition and are capable of safely and adequately heating all habitable rooms, bathrooms, and water closet compartments in every dwelling unit located therein to a temperature of at least 68°F at a distance three feet above floor level under ordinary minimum winter conditions.
(F) (1) Every public hall and stairway in every multiple dwelling containing five or more dwelling units shall be adequately lighted at all times.
(2) Every public hall and stairway in structures devoted solely to dwelling occupancy and containing not more than four dwelling units may be supplied with conveniently located light switches, controlling an adequate lighting system which may be turned on when needed, instead of full-time lighting.
(G) Every basement or cellar window used or intended to be used for ventilation, and every other opening to a basement which might provide an entry for rodents, shall be supplied with a screen or such other device as will effectively prevent their entrance.
(2011 Code, § 15.08.100) (Ord. 67, passed - -1974) Penalty, see § 152.99