D106 MULTIPLE-FAMILY RESIDENTIAL DEVELOPMENTS
   (A)   D106.1 Projects having more than 100 dwelling units.
      (1)   Multiple-family residential projects having more than 100 dwelling units shall be equipped throughout with two separate and approved fire apparatus access roads.
      (2)   Exception. Projects having up to 200 dwelling units may have a single approved fire apparatus access road when all buildings, including nonresidential occupancies, are equipped throughout with approved automatic sprinkler systems installed in accordance with Section 903.3.1.1 or 903.3.1.2. D106.2 Projects having more than 200 dwelling units.
      (3)   Multiple-family residential projects having more than 200 dwelling units shall be provided with two separate and approved fire apparatus access roads regardless of whether they are equipped with an approved automatic sprinkler system.
   (B)   D106.3 Remoteness. Where two fire apparatus access roads are required, they shall be placed a distance apart equal to not less than one-half of the length of the maximum overall diagonal dimension of the property or area to be served, measured in a straight line between accesses.
(Ord. O-11-20, passed 8-6-2020)