§ 154.304 OFF-STREET LOADING REQUIREMENTS.
   (A)   There shall be provided at the time any building is erected or structurally altered, off-street loading spaces in accordance with the following requirements:
      (1)   Office buildings:
 
5,000 to 25,000 square feet of GFA*
One 12 feet by 20 feet loading space
25,001 to 50,000 square feet of GFA
One 14 feet by 35 feet loading space
50,001 to 200,000 square feet of GFA
Two 14 feet by 35 feet loading spaces
Add one additional 14 feet by 35 feet loading space for each 75,000 square feet of gross floor area above 200,000 square feet.
*GFA means gross floor area.
 
      (2)   Retail or service establishment:
 
Less than 5,000 square feet of GFA
One 12 feet by 20 feet loading space
5,001 to 20,000 square feet of GFA
One 14 feet by 35 feet loading space
20,001 to 100,000 square feet of GFA
Two 14 feet by 35 feet loading spaces
Add one additional space for each 75,000 square feet of gross floor area above 1,000,000 square feet
 
      (3)   Wholesale, commercial use:
 
2,000 to 20,000 square feet of GFA
One 14 feet by 35 feet loading space
20,000 to 100,000 square feet of GFA
Two 14 feet by 35 feet loading spaces
Add one additional space for each 75,000 square feet of gross floor area above 100,000 square feet.
 
      (4)   Manufacturing or industrial use: One 14 feet by 35 feet space for each 10,000 square feet of gross floor area plus one 14 feet by 35 feet space for each portion thereof in excess of 50,000 square feet.
   (B)   Loading spaces are to be provided on each lot in compliance with the following requirements.
      (1)   The loading space shall be completely contained on the lot it is intended to serve.
      (2)   The loading space shall be arranged on the lot in such a way as to allow normal movement of traffic in and around the loading area.
      (3)   No loading space shall be permitted to extend into any public right-of-way.
(Ord. 0904-05, passed 5-20-2009) Penalty, see § 154.999