§ II-9.004 PLANS AND SPECIFICATIONS.
   (A)   Plans and specifications for all installations which receive human excreta, other than a conventional individual on-site wastewater system, must be submitted to the DANR for review and approval prior to construction. Installation and operation of such systems shall be in accordance with approved plans and specifications. Plans and specifications must be prepared by a state licensed engineer, and must be installed by a state licensed installer. The seal of registration must be on all plans and specifications.
   (B)   Design factors.
      (1)   Individual on-site wastewater systems shall be designed in accordance with the provisions of ARSD 74:53:01.
      (2)   For residential dwellings, the anticipated maximum daily flow shall be calculated at 75 gallons per person per day (minimum of three and one-half persons) or 120 gallons per bedroom per day, whichever is greater.
(Ord. 14-01, passed 6-6-2014, Ch. 9, § 1.4; Ord. 22-04, passed 4-11-2023; Ord. 24-02, passed 5-14-2024)