§ 152.08 APPLIANCES AND INSTALLATIONS.
   (A)   No gas appliances shall be installed or used except those approved by the American Gas Association or the Underwriter's Laboratories.
   (B)   All gas appliances shall be connected with the gas turned off and all appliance connections shall be tested with soap suds immediately after installation.
   (C)   No rubber hose or rubber tubing or lead pipe shall be used except for connecting appliances which are necessarily portable and then the connection must be of proper design, good quality and properly approved. In addition a shut-off valve must be provided readily accessible and firmly connected to the rigid pipe connection.
   (D)   All automatic gas water heaters must be provided with an approved automatic safety pilot. All water heaters shall be vented properly and shall never be installed in a bathroom or bedroom. All appliances designed and approved for venting shall be properly vented.
   (E)   All gas appliances shall be so located and installed so that they will be readily accessible for operation and adjustment and no appliance shall be installed in any location where the facilities for ventilation do not permit sufficient air for proper combustion at all times or where a hazard will be created by the installation.
('60 Code, § 5-16) (Ord. passed 6-3-57) Penalty, see § 152.99