1143.08 DESIGN STANDARDS FOR OFF-STREET LOADING AREAS.
   (a)   All off-street loading spaces must be located to the side or rear of the principal structure and screened in accordance with Section 1141.07 and are prohibited within any front yard.
   (b)   Required off-street loading spaces shall be provided access to and from a public street or alley by an access drive of at least ten (10) feet in width designed to permit convenient access by semi-trailer trucks.
   (c)   An off-street loading space shall consist of a rectangular area adequate for loading and unloading and be accessible from a maneuvering area.
   (d)   All off-street loading spaces and maneuvering areas shall be located on the same lot as the use they are intended to serve.
   (e)   A required off-street loading space shall have a clearance height of not less than fifteen (15) feet and shall have minimum dimensions of not less than twelve (12) feet in width and fifty (50) feet in length, exclusive of any driveway, aisle, or other circulation area.
   (f)   All unenclosed off-street loading areas, common areas and adjacent driveways shall be paved with asphalt material, cement, cobblestone, or brick pavers and parking spaces shall be striped.
   (g)   The number of off-street loading spaces required for various types of uses shall be no less than as set forth in the following:
CN, CG, and SI Districts: Each use in these Districts shall provide loading spaces based on gross floor area as follows:
Less than five thousand (5,000) square feet - none required.
Five thousand (5,000) to two hundred fifty Thousand (250,000) square feet = one (one) space.
Over two hundred fifty (250,000) square feet = one (1) space for each two (2) hundred fifty (250,000) square feet or portion thereof.
AM District: Each use in this District shall provide loading spaces based on gross floor area as follows:
Under ten thousand (10,000) square feet = none.
Ten Thousand (10,000) square feet or more but less than seventy-five thousand (75,000) square feet = one (1) space.
Seventy-five thousand (75,000) square feet or more but less than one hundred fifty thousand (150,000) square feet = two (2) spaces.
One hundred fifty thousand (150,000) square feet or more but less than three hundred thousand (300,000) square feet = three (3) spaces
Over three hundred thousand (300,000) square feet = one (1) space for each one hundred thousand (100,000) square feet or portion thereof.
   The loading space requirements for buildings with multiple uses or tenants shall be determined based on the aggregate total of gross floor area of all uses or tenants.
(Ord. 15-23. Passed 8-14-23.)