1111.03 SANITARY SEWERS.
   (a)   Concrete Encasement. Concrete encasement shall be used when required for the sanitary sewer to withstand trench loadings, when rock is encountered in the trench bottom, when the cover is less than two-and-one-half feet (2½’), or when such sewer line crosses a stream with year-round flow and where it crosses another utility line with less than eighteen inches (18”) separation.
   (b)   Testing. Testing shall be in accordance with the City Construction and Material Specifications.
   (c)   Building Sewers. Building sewers shall be constructed at no expense to the City. Before any building sewer is constructed, a tap permit must be obtained from the City. Installation of building sewers shall conform to applicable regulations of the City Division of Water Pollution Control. An ”S” shall be stamped into the face of the curb at the location of any building sewer tap.
(Ord. 5-01. Passed 2-26-01.)