§ 52.62 INTERIM DISCHARGE LIMITATIONS.
   No user shall discharge wastewater containing any of the following pollutants in excess of the following interim pollutant discharge limitations:
   (A)   Compatible pollutants:
      (1)   Any fats, oil or grease (FOG) in concentration greater than 1,500 mg/l based on an average of all samples collected within a 24 hour period.
      (2)   Any total suspended solids (TSS) in concentrations greater than 7.500 mg/l.
      (3)   Any biochemical oxygen demand (BOD) in concentrations greater than 7,500 mg/l.
      (4)   Any phosphorus (P) in concentrations greater than 250 mg/l.
   (B)   Unless otherwise stated, all limitations are based upon samples collected over an operating period representative of a user’s discharge, and in accordance with 40 C.F.R. Part 136.
   (C)   (1)   Non-compatible pollutants:
      (2)   Cadmium (Cd): 1.0 mg/l.
(Ord. 23.33, passed 2-9-09)