(A) Maximum permissible sound levels by receiving land use. No person shall operate or cause to be operated on private property any source of sound in such a manner as to create a sound level which exceeds the limits set forth for the receiving land use category in Table 2 when measured at or within the property boundary of the receiving land use. These maximum permissible sound levels are Leq: dB(A) values measured in accordance with the guidance provided in this section.
Table 1. Octave Bands Defined
| |
Frequency Range | Geometric Mean (or Center Frequency) of Octave Band |
Table 1. Octave Bands Defined
| |
Frequency Range | Geometric Mean (or Center Frequency) of Octave Band |
22-44 | 31.5 |
44-88 | 63 |
88-177 | 125 |
177-355 | 250 |
355-710 | 500 |
710-1420 | 1000 |
1420-2840 | 2000 |
2840-5680 | 4000 |
5680-11360 | 8000 |
Table 2. Sound Levels by Receiving Land Use
| ||
Land Use Category | Time | Maximum Permissible Sound Level Leq : dB(A) |
Table 2. Sound Levels by Receiving Land Use
| ||
Land Use Category | Time | Maximum Permissible Sound Level Leq : dB(A) |
A (noise sensitive zones) | At all times | 55 |
**B (residential) | 10:00 p.m. - 7:00 a.m. | 55 |
7:00 a.m. - 10:00 p.m. | 60 | |
C (Commercial) | 10:00 p.m. - 7:00 a.m. | 60 |
7:00 a.m. - 10:00 p.m. | 65 | |
D (Industrial) | At all times | 65 |
**From Friday 10:00 p.m. to Sunday 10:00 p.m. Residential Districts will be considered Noise Sensitive Zones. The maximum decibel level allowed is 55 at all times.
(B) Correction for character of sound. For any source of sound which emits a pure tone or impulsive sound, the maximum sound level limits set forth in § 91.18(A) shall be reduced by 3 dB(A). In addition, octave band frequency limits in dB as established in Table 3 (daytime) and Table 4 (nighttime) shall not be exceeded.
Table 3. Maximum Permissible Limits By Octave Band if Pure Tones Exist (Daytime)
| ||||
Octave Band Center Frequency | A Noise Sensitive Zones | B **Residential | C Commercial | D Industrial |
Table 3. Maximum Permissible Limits By Octave Band if Pure Tones Exist (Daytime)
| ||||
Octave Band Center Frequency | A Noise Sensitive Zones | B **Residential | C Commercial | D Industrial |
31.5 | 72 | 75 | 80 | 80 |
63 | 71 | 74 | 78 | 78 |
123 | 65 | 67 | 73 | 73 |
250 | 57 | 63 | 67 | 67 |
500 | 51 | 56 | 61 | 61 |
1000 | 45 | 51 | 56 | 56 |
2000 | 39 | 47 | 52 | 52 |
4000 | 34 | 45 | 48 | 48 |
8000 | 32 | 40 | 45 | 45 |
**Residential Districts shall be Noise Sensitive Zones from 10:00 p.m. Friday to 10:00 p.m. Sunday.
Table 4. Maximum Permissible Limits by Octave Band if Pure Tones Exist (Nighttime)
| ||||
Octave Band Center Frequency | A Noise Sensitive Zones | B **Residential | C Commercial | D Industrial |
Table 4. Maximum Permissible Limits by Octave Band if Pure Tones Exist (Nighttime)
| ||||
Octave Band Center Frequency | A Noise Sensitive Zones | B **Residential | C Commercial | D Industrial |
31.5 | 72 | 72 | 75 | 80 |
63 | 71 | 71 | 74 | 78 |
123 | 65 | 65 | 67 | 73 |
250 | 57 | 57 | 63 | 67 |
500 | 51 | 51 | 56 | 61 |
1000 | 45 | 45 | 51 | 56 |
2000 | 39 | 39 | 47 | 52 |
4000 | 34 | 34 | 45 | 48 |
8000 | 32 | 32 | 40 | 45 |
**Residential Districts shall be Noise Sensitive Zones from 10:00 p.m. Friday to 10:00 p.m. Sunday.
(Ord. 1218, passed 11-2-06) Penalty, see § 91.99(E)