Table B.2 - Maximum Wastewater Loading Rates
System types 1 and 2, and drip distribution systems shall use the most limiting soil loading rate 18 inches below the wastewater application point to size the soil absorption component. System Types 3, 4 & 5, and the Illinois Raised Filter Bed, shall use the most limiting soil loading rate in the upper 12 inches of soil to size the soil absorption component.
Till/ Lacustrine
Outwash
Till/ Lacustrine
Outwash
Gravelly coarse sand
0.00
0.00
Moderate or strong platy structure
0.00
0.00
Sandy clay loam, silty clay loam, or finer, and weak platy structure
0.00
0.00
Moist soil consistence stronger than firm or any cemented class
0.00
0.00
Sandy clay, clay, or silty clay texture and weak or massive structure
0.00
0.00
Sandy clay loam, clay loam, silty clay loam, silt, loam or silt loam texture and massive structure
0.00
0.00
Sandy clay, clay, or silty clay texture of low clay content and moderate or strong structure
0.20
0.20
Sandy clay loam, clay loam, silty clay loam or silt loam texture with weak structure
0.20
0.30
Clay loam, silty clay loam, or silt loam texture and moderate or strong structure
0.40
0.50
Sandy loam or loam texture and weak structure
0.40
0.50
Sandy clay loam, sandy loam, or loam texture and moderate or strong structure
0.50
0.70
Fine sand, very fine sand, loamy fine sand, or loamy very fine sand
0.60
0.70
Loamy sand, sand, or coarse sand texture
0.80
0.80
 
Whenever a NSF ANSI Standard Number 40 pretreatment unit is proposed, the wastewater loading rate may be increased
by a factor of 20% as follows:
0.20 —> 0.24
0.30 —> 0.36
0.40 —> 0.48
0.50 —> 0.60
0.60 —> 0.72
0.70 —> 0.84
0.80 —> 0.96
Whenever an NSF ANSI Standard Number 350 pretreatment unit is proposed, the wastewater loading rate may be increased by a factor of 100% as follows:
0.20 —> 0.40
0.30 —> 0.60
0.40 —> 0.80
0.50 —> 1.0
0.60 —> 1.2
0.70 —> 1.4
0.80 —> 1.6