(a) The final plat shall be clearly legibly drawn on reproducible mylar. The size of the plat shall be twenty-four inches by thirty-six inches. The plat of a subdivision containing five acres or less shall be drawn to a scale of one inch equals fifty feet. All other subdivisions shall be drawn to a scale of one inch equals 100 feet. The minimum lettering height shall be three thirty-seconds of an inch and all lot dimensions shall be one-eighth of an inch or larger. Lot number lettering shall be one-quarter of an inch or larger and underlined or circled.
(b) If the final plat is drawn in two or more sections, each section shall be accompanied by a key map showing the locations of the sections. All final plat sections shall either totally include or totally exclude intersections and all lots fronting such intersections.
(c) Construction drawings shall be submitted in the form stated in the City of Kenton Design Criteria. The plans shall consist of the required improvements stated in these Regulations.
(Ord. 97-022. Passed 1-12-98.)