1109.13 SIGN CONSTRUCTION AND MAINTENANCE.
   (a)   Material and Design. All signs must be designed, constructed, and maintained in conformity with the provisions for materials, loads and stresses of the latest adopted version of the Ohio Building Code and requirements of this Chapter.
   (b)   Fastenings. All signs must be erected in such a manner and with such materials to remain safe and secure during the period of use and all bolts, cables, and other parts of such signs must be kept painted and free from corrosion.
   (c)   Support Location. No pole, cable, or support of any nature will be placed on any publicly owned property, street, public right-of-way, or proposed public street right-of-ways.
   (d)   Proximity to Electrical Conductors. No sign will be erected so that any part including cables and guys will be within ten (10) feet of any electrical conductor, street lamp, traffic light or other public utility pole standard, or ten (10) feet of a high voltage wire.
   (e)   Sanitation. Property surrounding any sign must be kept clean, sanitary, and free from obnoxious and offensive substances, weeds, rubbish, and inflammable material.
   (f)   Maintenance. All signs must be maintained in a condition of good repair. Peeling or missing paint, holes, broken, cracked, bent, warped, rotted, discolored, sagging, out-of-plumb, rusted, or missing material or parts must be repaired within sixty (60) days of written notification by the Zoning Inspector.
(Ord. 2021-057. Passed 6-16-21.)