(a) Whenever deemed necessary, Director may require Users to restrict their Discharge during peak flow periods to the POTW, designate that certain Wastewater be Discharged only into specific Sewers, relocate and/or consolidate points of Discharge, separate Domestic Sewage waste streams from Non-Domestic Sewage waste streams, and such other conditions as may be necessary to protect the POTW and determine the User’s compliance with the requirements of this Ordinance.
(b) The Director may require any person discharging into the POTW to install and maintain, on their property and at their expense, a suitable storage and flow control facility to ensure equalization of flow Discharge into the POTW. A WDP may be issued solely for the purpose of flow equalization.
(c) FOG Control Devices and/or solids interceptors shall be provided when, in the opinion of the Director, they are necessary for the proper handling of Wastewater containing excessive amounts of FOG or solids. All FOG Control Devices shall be of a type and capacity approved by Director, shall comply with Section 915.08 of this Ordinance, and shall be so located to be easily accessible for cleaning and inspection. Such FOG Control Devices shall be inspected, cleaned, and repaired in accordance with Section 915.08 of this Ordinance by the User at their expense.
(d) Users with the potential to Discharge flammable substances to the POTW may be required to install and maintain an approved combustible gas detection meter(s).
(Ord. 2012-90. Passed 8-15-12.)