§ 154.066 STREET LIGHTS.
   (A)   Intersection lighting. Street lights shall be provided at each intersection of streets (or alleys) within a subdivision and at each cul-de-sac, but in no event shall there be less than one streetlight per 400 feet (or portion thereof) of street frontage between intersections, or between a street intersection and the terminus of a dead-end street. Additionally, in multi-family dwelling subdivisions, lighting shall be provided within parking areas at a minimum rate of one light per 25 parking spaces or any fraction thereof.
(1999 Code, § 34-5-32)
   (B)   Streetlight system standards.
      (1)   The design and installation of the streetlight system in every subdivision shall be reviewed by the Building Commissioner and the appropriate electric utility company.
      (2)   The lighting intensity of each streetlight shall be equivalent, at a minimum, to a 175 watt lamp or 6800 mercury luminary lamp. Each streetlight standard (post) shall be at least 16 feet high.
(1999 Code, § 34-5-33)