15.24.130: RAMADAS:
A.   A ramada may be erected, constructed or maintained on a mobile home lot as an accessory to a mobile home located on the same lot and conforming to state and city building codes.
B.   A ramada or any portion thereof shall have a clearance of not less than eighteen inches (18") in a vertical direction above any gas burning appliance vent or plumbing vent extending through the roof of a mobile home and not less than six inches (6") in a horizontal direction from each side of a mobile home. Cross braces, architectural appurtenances or structural ties, shall not obstruct movement of any mobile home.
C.   A ramada shall be designed and erected as a freestanding self- supporting structure meeting requirements for cabanas.
D.   A ramada shall not be enclosed or partially enclosed on any side or end, except that one side may be enclosed with the ramada roof continuous with the roof of a cabana constructed on one side only of any mobile home.
E.   A ventilating opening shall be installed at the highest point in the ramada roof to relieve products of combustion from vents or ducts of fuel burning equipment. Vent openings shall have a minimum cross section of twenty eight (28) square inches. Chimneys or vents of appliances burning solid or liquid fuel shall extend through the ramada roof surface and shall terminate in an approved roof jack and cap. (Ord. 628 §13, 1980)