(A) Construction of water mains. Where public water supply is available within 2,000 feet of any boundary of the proposed subdivision, the subdivider shall construct a system of water mains, connected with such public water supply and provide a connection with each lot. The work shall be done in accordance with the plans, profiles and specifications prepared by a registered professional engineer and shall be approved by the city or town engineer of any participating city or town and be in conformance with at least the minimum requirements of the State Board of Health, Regulation H.S.E., 5,1.S.B.H.
(B) Distribution system. No pipe smaller than six inches in diameter shall be permitted. Six-inch pipe shall be limited to lengths of not over 800 feet unless looped. In high value districts, so designated for purposes of fire protection and prevention, distributors shall be not less than eight inches and cross-connected within 800 feet. On primary streets and for all long lines, distributors shall be 12 inches or larger.
(C) Valves. Valves shall be installed so that no single accident, break repair or extension will necessitate shutting down a length of pipe greater than 500 feet in high value districts or greater than 1,000 feet in other districts so that flows may be maintained through arterial mains.
(D) Community or individual water supply. Where public water supply is not available within 200 feet of any boundary of the proposed subdivision, and where the Commission determines that connection thereto would create a hardship for the subdivider, the subdivider may provide each lot with a community or individual water supply provided that installation conforms to at least the minimum requirements of the State Board of Health Bulletin No. S.E. 7, Safe Water Supply, Current Issue. Upon the completion of the water supply system, the plans for such system as built shall be filed with the Commission, the County Surveyor if the installation is within the unincorporated area of the county, with the City Engineer if within the North Vernon corporate limits, with the Town Board of Vernon, or any participating town.
(Ord. 2, passed 8-14-2006) Penalty, see § 10.99