4-2-2: AMENDMENTS, DELETIONS, ADDITIONS AND MODIFICATIONS:
The following amendments, deletions, additions and modifications are hereby made to the Inverness building code as adopted in section 4-2-1 of this chapter:
Sections 101.4.1, 101.4.4, 101.4.7, 103, 104.1, 104.2, 104.3, 104.5, 104.7, 105.1, 105.1.1, 105.1.2, 105.2, 105.2.1, 105.2.2, 105.2.3, 105.3, 105.3.1, 105.3.2, 105.4, 105.5, 106.3.2, 106.3.3, 109.1, 109.2, 109.3, 110.2, 112, 112.1, 112.2, and 112.3 of the IBC are hereby deleted and are not adopted as parts of the Inverness nonresidential building code.
Section 101.1 shall be and is hereby amended to read as follows:
101.1 Title. These regulations shall be known as the "Inverness non-residential building code", hereinafter sometimes referred to as "this code".
Section 101.2 shall be and is hereby amended to read as follows:
101.2 Scope. The provisions of this code shall apply to the construction, alteration, movement, enlargement, replacement, repair, equipment, use and occupancy, location, maintenance, removal and demolition of every building or structure or any appurtenances connected or attached to such buildings or structures.
Exceptions:
1.   Detached one- and two-family dwellings and multiple single-family dwellings (townhouses) not more than two stories above grade plane in height (plus any mezzanine as authorized by this code) with a separate means of egress and their accessory structures shall comply with the Inverness residential building code.
2.   All other existing buildings shall comply with this code, the Inverness non-residential building code.
Section 101.4 shall be and is hereby amended to read as follows:
101.4 Referenced Codes. The other codes referenced in this code shall be considered part of the requirements of this code in their entirety.
Section 101.4.5 shall be and is hereby amended to read as follows:
101.4.5 Property Maintenance. The provision of the international property maintenance code (2003), which is hereby adopted, shall apply to existing structures and premises; equipment and facilities; light, ventilation, space heating, sanitation, life and fire safety hazards; responsibilities of owners, operators and occupants; and occupancy of existing premises and structures.
Section 101.4.6 shall be and is hereby amended to read as follows:
101.4.6 Fire Prevention. The provisions of the international fire code (2003), which is hereby adopted, shall apply to matters affecting or relating to structures, processes and premises from the hazard of fire and explosion arising from the storage, handling or use of structures, materials or devices; from conditions hazardous to life, property or public welfare in the occupancy of structures or premises; and from the construction, extension, repair, alteration or removal of fire suppression and alarm systems or fire hazards in the structure or on the premises from occupancy or operation, provided, however, section 903.2.7 of the international fire code (2003) shall be amended to provide as follows:
"903.2.7 Group R. An automatic sprinkler system installed in accordance with section 903.3 shall be provided throughout all buildings with a group R fire area, provided, however, that this requirement shall not be applicable to R-3 residential occupancies as defined in said fire code, except where and in the manner that automatic sprinkler systems are otherwise required by this village code."
Section 107.9.1 of the Inverness nonresidential building code shall be and is hereby amended to read as follows:
107.9.1 Accessory Buildings Or Structures. It shall be unlawful to build any garage, shed or other accessory building or structure before the main building is built on the subject property, and no building permit shall be issued for same, before the main building is built on the subject property, and no accessory building shall be used as a residence.
Section 1807.4.3 shall be and is hereby amended to read as follows:
Section 1807.4.3 Drainage Discharge. Any floor base and foundation perimeter drain hereinafter installed shall discharge by mechanical means or by a combination of mechanical means and gravity into an approved drainage system that complies with the Inverness plumbing code. However, systems relying only on gravity shall not be permitted.
Section 2701 and this code in its entirety are hereby amended by the deletion of all references to the ICC electrical code and the substitution in lieu thereof of a reference to the national electrical code, 2005.
Section 3410.2 is hereby amended by the insertion as the date of adoption of this Inverness nonresidential building code, the words "the effective date of this code and title".
Chapters 29, 30 and 32, and appendices A, B, C, D, E, G, H, I, and J of the IBC are hereby deleted and not adopted as part of the Inverness nonresidential building code.
(Ord. 06-822, 3-14-2006)