11-2-5: REQUIRED INFORMATION AND DATA:
   A.   Sketch Plan: Sketch plans shall contain, as a minimum, the following information:
      1.   Tract boundaries.
      2.   North point.
      3.   Streets on and adjacent to the tract.
      4.   Significant topographical and physical features.
      5.   Proposed general street layout.
      6.   Proposed general land use.
      7.   Name of owner and/or developer.
      8.   Zoning on and adjacent to tract.
   B.   Preliminary Plat: A preliminary plat shall contain the following information:
      1.   Identification And Description:
         a.   Proposed name of subdivision, which name shall not duplicate or be similar to the name of any other plat.
         b.   Location by section, town, range or by other legal description.
         c.   Names and addresses of the owner, subdivider, surveyor and designer of the plan.
         d.   Graphic scale.
         e.   North point.
         f.   Date of preparation.
         g.   Certification by surveyor certifying to accuracy of survey.
      2.   Existing Conditions:
         a.   Boundary line of proposed subdivision clearly indicated.
         b.   Existing zoning classification, if any.
         c.   Total acreage.
         d.   Location, widths and names of all existing or previously platted streets or other public ways, showing type and width and condition of improvements, if any, railroad and utility rights of way, parks and other public spaces, permanent buildings and structures, easements and section and corporate line within the tract, and to a distance of one hundred feet (100') beyond the tract. Such data as grades, invert elevations and locations of catch basins, manholes and hydrants, if any, shall also be shown.
         e.   Boundary lines of adjoining unsubdivided or subdivided land within one hundred feet (100'), identifying by name and ownership.
         f.   Topographical data, including contours at vertical intervals of not more than two feet (2'), except that contour lines shall be no more than one hundred feet (100') apart. Watercourses, marshes, wooded areas, rock outcrops, power transmission poles and lines, buildings and other significant features shall also be shown.
         g.   All elevations, topography and vertical control data shall be tied to sea level datum 1929 general adjustments. Temporary bench marks shall be established within the boundaries of the subdivision. Descriptions, reference ties and elevations of the bench marks shall be furnished to the city engineer.
         h.   Reference to recorded subdivision plat or adjoining platted land by record, name, date and number.
         i.   The location and size of all existing sanitary sewers, water or storm sewers, trunks, laterals or services on or adjacent to the property.
      3.   Design Features:
         a.   Primary control points, with descriptions and ties to such control points to which all dimensions, angles, bearings and similar data on the plan shall be referred.
         b.   Tract boundary lines, right of way lines of streets, easements and other rights of way and property lines of residential lots and other sites, with accurate dimensions, bearings or deflection angles and radii, arcs and central angles of all curves.
         c.   Name and right of way width of each street or other right of way.
         d.   Location, dimensions and purpose of any easements.
         e.   An identification system for all lots and blocks.
         f.   Site data including number of residential lots, typical lot size, and acres in park, etc.
         g.   Sites, if any, to be reserved for parks or other public uses.
         h.   Sites, if any, for multi-family dwellings, shopping centers, churches, industry or other nonpublic uses exclusive of single- family dwellings.
         i.   Minimum building setback line on all lots and other sites with the width of lot shown at setback line.
         j.   Location and description of monuments.
      4.   Preliminary Grading And Drainage Plan: A preliminary grading and drainage plan including earthwork quantities, final grades (3:1 maximum slopes, 4:1 preferred maximum), building pad elevations, existing and proposed topography at two foot (2') intervals, drainage calculations, 10-year storm pipe design, 100-year storm level of protection, direction of drainage around each building pad location, and appropriate easements as required.
      5.   Preliminary Erosion Control Plan: A preliminary erosion control plan including method, location and detail of erosion control measures.
      6.   Preliminary Utility And/Or On Site Sewage Treatment Plan:
         a.   Plan and profile showing existing utilities, proposed utilities, connection with existing utilities (water main, sanitary sewer, storm sewer), and appropriate easements as required.
         b.   Note whether utilities will be publicly or privately constructed, owned and maintained.
         c.   For plats in the unsewered portion of the city, two (2) drainfield locations shall be shown for each proposed lot. (Must be located in undisturbed soil.)
      7.   Preliminary Street Plan: Plan and profile showing internal roads, grades, lengths of cul-de-sacs, curb data (horizontal and vertical), connection to existing streets or platted rights of way, provisions for future extensions or connections to adjacent land, and appropriate easements or rights of way.
      8.   Preliminary Wetland Plan: Plan showing fill or draining of any wetland including sequencing justification and proposed mitigation consistent with the wetland conservation act1. All wetlands must be delineated in accordance with the wetland conservation act.
      9.   Preliminary Tree Preservation Plan: Plan showing location, size and species of all significant trees (8 caliper inches or greater for deciduous trees, 10 feet in height for coniferous trees) within thirty feet (30') of grading limits, including those trees to be preserved and those to be removed.
      10.   Preliminary Reforestation Or Landscape Plan: Plan showing reforestation required by title 10, chapter 15, article D of this code and landscaping required by section 10-15-11 of this code. The plan must identify location, size, species and quantity of plant materials.
      11.   Urban Development Concept Plan: All lands designated for residential development by the comprehensive plan that are located within the A agricultural and E-1 and E-2 estate zoning districts are outside of the metropolitan urban service area (MUSA), and have a gross land area of twenty (20.0) acres or more shall provide a concept plan indicating the manner in which land could be developed at urban densities. The urban development concept plan should be designed to current subdivision standards for urban development. In designing the subdivision, the following considerations should be made:
         a.   The proposed street layout for the urban subdivision overlay may, at the discretion of the city council, be required to integrate with the rural plat to maximize the use of existing built roadways and connections to off site systems. All street rights of way for the urban development concept plan may, at the discretion of the city council, be required to be platted as part of the rural plat to secure the integrity of future urban platting.
         b.   Lot size and arrangement may, at the discretion of the city council, be required to be based on the R-1C one-family residential district standards. House pad locations for the rural development may, at the discretion of the city council, be required to be indicated on the concept plan and be consistent with urban zoning standards so as to maximize efficient resubdivision of the rural lots into urban lots.
         c.   Areas for potential park land dedication and trail connections shall be identified as outlots that are suitable for dedication to the city if required by the city council.
         d.   The potential location of easements for drainage, municipal water, sanitary sewer, and storm sewer systems may, at the discretion of the city council, be required to be shown in the urban development concept plan, including connection points for utility systems at the plat boundaries. Such easements may be required to be dedicated together with the rural plat if the city council requires it.
         e.   The preliminary storm drainage system design may, at the discretion of the city council, be required to include proper pipe sizing and storm water ponding improvements for the urban development.
         f.   This urban development concept plan shall be submitted together with the application for final plat.
      12.   Letter Regarding County Or State Rights Of Way: Letter from the county and/or MN/DOT containing recommendations and/or regulations on access or right of way requirements, if the property abuts county or state roads or rights of way, or proposes access to a state or county road.
      13.   Supplementary Data: The following supplementary data shall be supplied with preliminary plat:
         a.   Names of record owners of adjoining unplatted land.
         b.   Protective covenants in form for recording, if any.
         c.   Other information such as certificates, affidavits, endorsements, photographs, traffic studies or other information as may be required by the city council and/or the planning commission and/or city staff in the enforcement of this title.
         d.   Soil borings and analysis, if required by the city engineer or chief building official.
         e.   Evidence that ground water control is at least ten feet (10') below the level of finished grades or plan for solving ground water problems, if required by the city engineer.
         f.   The size and dimension of all lots.
         g.   Notarized certification by owner and by any mortgage holder of record of the adoption of the plat and the dedication of streets and other public areas.
   C.   Final Plat:
      1.   The final plat shall be on sheets twenty inches (20") wide by thirty inches (30") long and shall be at a scale of one hundred feet equals one inch (100'=1") or such other standard scale as approved by the city engineer, and in all other respects shall comply with Minnesota statutes. Where necessary, the final plat may be on several sheets accompanied by a key map showing the entire subdivision. For large subdivisions, the final plat may be submitted for approval progressively in contiguous sections satisfactory to the city council. The final plat shall contain the following information:
         a.   Certifications showing that all taxes due on the property to be subdivided have been paid in full.
         b.   An attorney's opinion of title showing title or control of the property to be subdivided in the application.
         c.   Name of the subdivision, which shall not duplicate or too closely approximate the name of any existing subdivision.
         d.   Location by section, township, range, county and state, and including descriptive boundaries of the subdivision, based on an accurate traverse, giving angular and linear dimensions which must mathematically close. The allowable error closure of any portion of a final plat shall be one foot (1') in seven thousand five hundred feet (7,500').
         e.   The location of monuments shall be shown and described on the final plat. Locations of such monuments shall be shown in reference to existing official monuments on the nearest established street lines, including true angles and distances to such reference points or monuments.
         f.   Location of lots, streets, public highways, alleys, parks and other features, with accurate dimensions in feet and decimals of feet, with the length of radii and/or arcs of all curbs, and with all other information necessary to reproduce the plat on the ground shall be shown. Dimensions shall be shown from all angle points of curb to lot lines.
         g.   Lots shall be numbered clearly. Blocks are to be numbered with numbers shown clearly in the center of the block.
         h.   The exact locations, widths and names of all streets.
         i.   Locations and widths of all easements.
         j.   Name and address of surveyor making the plat.
         k.   Scale of plat (the scale to be shown graphically on a bar scale), date and north arrow.
         l.   Statement dedicating all easements as follows: Drainage facilities are reserved over, under, and along the strips marked "utility easements".
         m.   Statement dedicating all streets, alleys and other public areas not previously dedicated as follows: Streets, alleys and other public areas shown on this plat and not heretofore dedicated to public use are hereby so dedicated.
         n.   Certification by registered surveyor in the form required by Minnesota statutes section 505.03, as amended.
         o.   Execution of all owners of any interest in the land and any holders of a mortgage thereon of the certificates required by Minnesota statutes section 505.03, as amended, and which certificate shall include a dedication of the utility easements and other public areas in such form as approved by the city council.
         p.   Space for certificates of approval and review to be filled in by the signatures of the chair and secretary of the city planning commission and the mayor and deputy city clerk.
      2.   Additional plans to be submitted with the final plat include the following:
         a.   Final Utility Plan:
            (1)   Plan and profile showing existing utilities, proposed utilities, connection with existing utilities (water main, sanitary sewer, storm sewer), and appropriate easements as required.
            (2)   Note whether utilities will be publicly or privately constructed, owned and maintained.
            (3)   For plats in the nonutilitied portion of the city, note drainfield locations on proposed lots. (Must be located on undisturbed soil.)
b. Final Wetland Plan: Plan showing fill or draining of any wetland including sequencing justification and proposed mitigation consistent with the wetland conservation act1. All wetlands must be delineated in accordance with the wetland conservation act.
         c.   Final Tree Preservation Plan: Plan showing location, size and species of all significant trees (8 caliper inches or greater for deciduous trees, 10 feet in height for coniferous trees) including trees to be preserved and removed and those within thirty feet (30') of grading limits.
         d.   Final Reforestation Or Landscape Plan: Plan showing reforestation required by title 10, chapter 15, article D of this code and landscaping required by subsection 10-15-11A of this code. The plan must identify location, size, species and quantity of plant materials.
         e.   Soil Borings And Analysis: Soil borings and analysis to show existence of suitable soils to accommodate two (2) septic system sites, per title 8, chapter 5 of this code.
         f.   Final Street Plans: Final street plans for requirements established in chapter 3 of this title.
         g.   Urban Development Concept Plan: All subdivisions required by the city council to conform to the standards of the urban development concept plan found in subsection B11 of this section must submit the necessary documents to implement the plan in the future. (Ord. 1038, 7-8-2002)