1049.03 NONRESIDENTIAL DEVELOPMENTS ON PUBLIC STREETS.
   (a)   Installation. The developer of a nonresidential development on public streets shall coordinate with the Detroit Edison Company and the City on all plans for the installation of street lighting during the site plan process as set forth in the Zoning Code. All street lighting installed shall be of the Granville Style Pole and Fixture and be installed pursuant to Detroit Edison's Municipal Street Lighting Program.
   (b)   Design Standards; Determination and Approval of Spacing and Layout by Planning Commission. All street lights in nonresidential developments on public streets shall be twelve-foot poles with fixtures containing 100 watt, high-pressure sodium lamps. The spacing between street lights and the layout of said lights shall be determined and approved by the Planning Commission after recommendations are received and reviewed from the Detroit Edison Company and an engineer of the developer's choosing. In no event shall the spacing between each light pole be less than sixty feet or more than 225 feet. The nonresidential development shall obtain a lighting level of .3 to .4 footcandle throughout the entire development.
   (c)   Costs of Installation. All costs of installation shall be borne by the developer of the nonresidential development.
   (d)   Costs of Operation, Maintenance and Replacement. On and after the acceptance of the streets and street lights in the nonresidential development by the City, the City shall be responsible for all costs associated with said street lights, including, but not limited to, the cost of operation, maintenance and replacement.
(Ord. 595. Passed 12-13-93.)