(a) Installation. The developer of a residential development on public streets shall coordinate with the Detroit Edison Company and the City on all plans for the installation of street lighting during the site plan process as set forth in the Zoning Code. All street lighting installed shall be of the Granville Style Pole and Fixture and be installed pursuant to Detroit Edison's Municipal Street Lighting Program.
(b) Design Standards. All street lights in residential developments on public streets shall be twelve- foot poles with fixtures containing 100 watt, high pressure sodium lamps. All street lights shall be spaced in an alternating pattern with the space between each light pole to be no less than 150 feet and no more than 225 feet. The residential development shall obtain a lighting level of .3 footcandle throughout the entire development.
(c) Costs of Installation. All costs of installation shall be borne by the developer of the residential development.
(d) Costs of Operation, Maintenance and Replacement. On and after the acceptance of the streets and street lights in the residential development by the City, the City shall be responsible for all costs associated with said street lights, including, but not limited to, the cost of operation, maintenance and replacement.
(Ord. 595. Passed 12-13-93.)