§ 158.522 ADDITIONAL INFORMATION.
   In addition to the uniform application requirements specified in KRS 100.985 - 100.987, applicants for a cellular antenna tower should submit the following information to staff prior to the required pre-application conference to assure a quick and judicious review of the submittal.
   (A)   A statement demonstrating that the proposal is in agreement with the Comprehensive Plan, and that the applicant has attempted to co-locate the proposed facility on an existing approved tower or facility or locate on sites that might be in better conformance with the adopted Comprehensive Plan, and that:
      (1)   Identifies the location of the sites attempted to locate; and
      (2)   Lists the reasons why the co-location or locating on the alternative sites was unsuccessful in each instance.
   (B)   A development site plan, signed and sealed by a professional engineer registered in Kentucky, drawn to a scale not smaller than one inch equals 100 feet, showing the following information, where applicable. The staff may waive the submission of such data involving detailed engineering study until such time as the application has been approved.
      (1)   The total area of the site in question;
      (2)   All rights-of-way and easement lines located on or adjacent to the subject property which are proposed to be continued, created, enlarged, relocated, or abandoned;
      (3)   Existing topography, and approximate delineation of any topographical changes shown by contour with intervals not to exceed five feet;
      (4)   Location, height, arrangement, and identification of all nonresidential buildings, structures, and uses on the subject property and, where applicable, location and arrangement of all lots with lot dimensions;
      (5)   A circle drawn on the site plan showing the setback distance requirement;
      (6)   Landscaping features, including identification of planting areas and the location, type, and height of walls and fences;
      (7)   Location of signs, indicating their orientation, size, and height;
      (8)   All electric utility lines and easements;
      (9)   Locations of all off-street parking, loading and/or unloading, and driveway areas, including typical cross sections, the type of surfacing, dimensions, and the number and arrangement of off- street parking and loading and/or unloading spaces.
(Ord. 10-2020, passed 5-19-2020)