§ 151A.08 SAFE AND SANITARY MAINTENANCE.
   (A)   Exterior foundation, walls, and roofs. Every foundation wall, exterior wall, and exterior roof shall be substantially weather tight and rodent proof; shall be kept in sound condition and good repair; shall be capable of affording privacy; shall be safe to use and capable of supporting the load which normal use may cause to be placed thereon. Every exterior wall shall be protected with paint or other protective covering to prevent the entrance or penetration of moisture or the weather.
   (B)   interior floors, walls, and ceilings. Every floor, interior wall, and ceiling shall be substantially rodent proof; shall be kept in sound condition and good repair; and shall be safe to use and capable of supporting the load which normal use may cause to be placed thereon.
   (C)   Windows and doors. Every window, exterior door, basement or cellar door, and hatchway shall be substantially weather tight, watertight, and rodent proof; and shall be kept in sound working condition and good repair.
   (D)   Stairs, porches, and appurtenances. Every outside and inside stair, porch, and any appurtenance thereto shall be safe to use and capable of supporting the load that normal use may cause to be placed thereon; and shall be kept in sound condition and good repair.
   (E)   Bathroom floors, toilet, bath and shower spaces. Bathtub and shower floors and walls above bathtubs with installed shower heads and in shower compartments shall be finished with a non-absorbent surface. Such non-absorbent surfaces must extend at least six feet above the floor. Every bathroom floor surface and water closet compartment floor surface shall be constructed and maintained so as to permit such floor to be easily kept in a clean and sanitary condition.
   (F)   Supplied facilities. Every supplied facility, piece of equipment, or utility which is required under this chapter shall be so constructed or installed that it will function safely and effectively, and shall be maintained in satisfactory working condition.
   (G)   Drainage. Every yard shall be properly graded so as to obtain thorough drainage and so as to prevent the accumulation of stagnant water.
   (H)   Noxious weeds. Every yard and all exterior property areas shall be kept free of species of weeds or plant growth which are noxious or detrimental to health.
   (I)   Egress. Every dwelling unit shall be provided with adequate means of egress as required by the current version of the North Carolina State Residential Building Code or the building code in effect at the time of construction, whichever is the least restrictive. All interior egress doors and a minimum of one exterior egress door shall be readily openable from the side from which egress is to be made without the use of a key or special knowledge or effort.
   (J)   Smoke alarms. Every dwelling and dwelling unit shall have smoke alarms installed and maintained according to the North Carolina State Residential Building Code.
(Ord. 10-04, passed 2-9-10) Penalty, see § 151A.99