(A) If the manufactured (mobile) home has had or is to receive a replacement furnace or water heater, it shall be listed for use in a manufactured (mobile) home and meet minimum requirements of the HUD standards contained in 24 C.F.R. § 42.3280.710. Vents, roof jacks and chimneys necessary for the installation shall be listed for use with the furnace or water heater.
(B) The furnace and water heater shall be secured in place to avoid displacement. Every furnace and water heater shall be accessible for servicing and/or replacement.
(C) Furnaces and water heaters shall be installed to provide complete separation of the combustion system from the interior atmosphere of the manufactured home as required by the HUD standards contained in 24 C.F.R. § 42.3280.709.
(D) The floor in the water heater area shall be free from damage from moisture and the like to assure that the floor will support the weight of the water heater and water contained within.
(Prior Code, § 151.10) (Ord. 576, passed 4-2-1996)