147.20    INDIVIDUAL WATER RISER PIPES AND CONNECTIONS.
   1.   Individual water riser pipes shall be located within the confined area of the mobile home stand as near to the center from front to back as possible and at a point where the water connection will approximate a vertical position, as near to the center of the stand as possible.
   2.   Water riser pipes shall extend at least to ground level. The pipe shall be at least three-fourths inch. The water outlet shall be capped when a mobile home does not occupy the lot.
   3.   Adequate provisions shall be made to prevent freezing of service lines, valves and riser pipes from heaving and thawing actions of ground during freezing weather. Surface drainage shall be diverted from the location of the riser pipe.
   4.   A shut-off valve below the frost line shall be provided near the water riser pipe on each mobile home lot.
   5.   Underground stops and water valves shall be installed and connected to the water supply as required by Water Department regulations.
   6.   Water meter pits and water meters shall be installed for each mobile home and building using water. The meter pit shall be located in a manner free and clear from obstruction, i.e., not located under mobile homes.
   7.   There shall be a water meter set at the connection point to the City mains.