8-3-7: RECIRCULATION AND FILTERING:
   A.   All swimming pools shall be underground type. Underground pools in sloping areas of the property may be a maximum of two feet six inches (2'6") above grade for not more than fifty percent (50%) of the pool area. (Ord. 351-85, 4-9-1985)
   B.   The swimming pool's recirculation system shall consist of pumping equipment, hair and lint catcher, filters, together with the necessary pipe connections to the pool inlets and outlets, facilities and pipe connections necessary for backwashing filters, and facilities and equipment for disinfecting the pool water.
   C.   Every swimming pool shall have a recirculating system with an hourly capacity equal to the pool volume divided by eight (8).
   D.   The recirculation system pump shall have sufficient capacity to discharge the volume of water required for an eight (8) hour turnover of the pool against the maximum head in the recirculating system.
   E.   The pump used for backwashing filters shall have sufficient capacity to provide a filter backwash rate of at least twelve (12) gallons per minute per square foot of filter area.
   F.   A hair and lint catcher or strainer shall be installed on the suction side of the circulation pump to prevent hair, lint and other extraneous matter from reaching the pump and filters. Hair and lint catchers shall be so designed that they can be easily dismantled for the cleaning and inspection and shall be so located as to be easily accessible for cleaning. The design features shall be as follows: water passes through the strainer from the outside; the strainer is made of noncorrosive material; the width or diameter of strainer openings is not more than one-eighth inch (1/8"); the area of the strainer openings shall be at least five (5) times the cross-sectional area of the inlet pipe to the strainer.
   G.   Recirculating systems shall contain rapid pressure filters. Sufficient filter area shall be provided to filter the entire contents of the pool in eighteen (18) hours at the rate of not more than three (3) gallons per square foot of filter area per minute. The filter backwashing facilities shall be sufficient to backwash at a rate of twelve (12) gallons per minute per square foot of filter area. All backwash water and effluents shall be discharged to the sewer through an indirect connection. Pressure filters shall be equipped with readily accessible air relief valves, loss of head or pressure gauges on the inlet and outlet pipes, and an access head or hole large enough to permit inspection, maintenance and repair work. Sight glasses that can be easily removed for cleaning shall be provided in the effluent line from the filter units. (Ord. 186-70, 7-13-1970)