Blocks within a subdivision shall conform to the following standards:
(A) Sizes.
(1) Maximum length for blocks shall not exceed 660 feet in length, except where in the opinion of the Commission, conditions may justify a greater distance.
(2) Widths of blocks shall be determined by the condition of the layout and shall be suited to the intended layout.
(B) Public walkways.
(1) Location of public walkways or crosswalks may be required by the Commission to obtain satisfactory pedestrian access to public or private facilities such as, but not limited to, schools and parks.
(2) Widths of public walkways or crosswalks shall be at least five feet and shall be in the nature of an easement for this purpose. Pavement widths shall not be less than four feet.
(C) Easements.
(1) Location of utility line easements shall be provided along the rear or side lot lines as necessary for utility lines. Easements shall give access for every lot, park, or public grounds. Such easements shall be a minimum of 14 feet, and preferably 20 feet. Half of the total comes from each lot line.
(2) Recommendations on the proposed layout of telephone and electric company easements should be sought from all of the utility companies serving the area. It shall be the responsibility of the subdivider to submit copies of the approved preliminary plat to all appropriate public utility agencies.
(3) Whenever possible, the subdivider shall be encouraged to design for the placement of utility lines underground, following the required standards and specifications established by each utility company.
('88 Code, § 10-12-2) (Ord. 82-5, passed 4-26-82; Am. Ord. 94-2, passed 4-4-94)