(a) Minimum Number of Loading Spaces Required: A loading space shall consist of a rectangular area of one of the following classes:
(1) Class A: An area at least fourteen feet by fifty-five feet (14' x 55') having a vertical clearance of fifteen (15) feet or more, plus adequate area for ingress and egress.
(2) Class B: An area at least twelve feet by thirty feet (12' x 30') having a vertical clearance of fifteen (15) feet or more, plus adequate area for ingress and egress.
(b) Schedule of Loading Spaces: Loading space shall be provided for retailing, wholesaling, warehousing, processing, and similar activities or uses in accordance with the following schedule:
Activity or Use | Class Required |
Building area less than seven hundred and fifty (750) square feet: | None required. |
Building area more than seven hundred and fifty (750) square feet but less than fifteen hundred (1,500) square feet: | One (1) Class B space required. |
Building area fifteen hundred (1,500) square feet but less than twenty-five hundred (2,500) square feet: | One (1) Class A space or two (2) Class B spaces required. |
Building area twenty-five hundred (2,500) square feet but less than ten thousand (10,000) square feet: | One (1) Class A space and one (1) Class B space, or three (3) Class B spaces required. |
Building area ten thousand (10,000) square feet but less than fifty thousand (50,000) square feet: | One (1) Class A space and one (1) Class B space, or three (3) Class B spaces, plus one (1) Class A space for each ten thousand (10,000) square feet over ten thousand (10,000) square feet of building area. |
Building area fifty thousand (50,000) square feet or more: | One (1) Class A space for each ten thousand (10,000) square feet over ten thousand (10,000) square feet of building area, plus one (1) Class A space for each twenty-five thousand (25,000) square feet over fifty thousand (50,000) square feet of building area. |