SEC. 9-4-181 DEVELOPMENT STANDARDS.
   (A)   No principal or accessory structure shall be closer than 25 feet to a public street right-of-way or private street easement.
   (B)   Side and rear setbacks and/or separation between buildings or opposing wings of a building vary according to the type of wall involved.
      (1)   Primary wall. Six feet plus two feet for each story plus one foot for each ten feet of wall length.
         Formula: D = 6+2S+L/10
         where D is the minimum setback distance, S is the number of stories, and L is the length of wall.
      (2)   Secondary wall. Two feet plus one foot for each story plus one foot for each ten feet of wall length.
         Formula: D = 2+S+L/10.
      (3)   Windowless wall. Ten feet.
   (C)   No structure or building may exceed 90 feet in height above the property grade unless the depth of the public or private street setback is increased five feet for each ten feet, or fraction thereof, of building height in excess of 90 feet.
   (D)   All off-street parking areas designed for three or more spaces shall be in accordance with Article O.