§ 154.104 GENERAL CONSTRUCTION REQUIREMENTS.
   (A)   Before installing piping, the contractor shall carefully verify the location, depth, type of joint needed and size of the pipe to which a connection is proposed. The contractor shall ensure that the lines can be run as contemplated without interfering with footings, walls, other piping, fixtures and the like.
   (B)   All sanitary sewers shall be installed within street rights-of-way unless otherwise approved by the town.
   (C)   Sanitary sewers shall be located so as to provide a minimum horizontal separation of ten feet from any existing or proposed water mains. Where sewers cross perpendicular to water lines, a minimum of 18 inches of vertical separation shall be maintained.
   (D)   All lengths of pipe shall be dimensioned accurately to measurements established at the site and shall be worked into place without springing or forcing. Cut sections of pipe shall be reamed to remove all burrs.
   (E)   The pipe shall be thoroughly cleaned before being laid and kept clean during construction.
(Ord. 2010-3, passed 10-6-2010)