§ 152.061  GENERAL REQUIREMENTS.
   The following are general requirements for the design and construction of manufactured home parks.
   (A)   Park identification sign. Manufactured home park identification signs are limited to one sign per park entrance. No sign may exceed 36 square feet in area. The sign must be located on private property and no closer than five feet from any property line and at least 20 feet from any dwelling unit. The sign must be set back at least ten feet from any public road right-of-way. In addition, one sign may indicate the office, if an office exists within the manufactured home park.
   (B)   Administrative office.  Within a manufactured home park, one manufactured home may be used as an administrative office.
   (C)   Storage buildings.  A manufactured home park may have material and equipment storage buildings for maintenance of the park.
   (D)   Drainage.  All ditch banks shall be sloped and seeded to prevent erosion, or vegetated buffer strips shall be maintained in their natural state to prevent erosion.
   (E)   Flood area.  The park shall be graded so as to prevent any water from ponding or accumulating on the premises.
   (F)   Mail service.  Space shall be provided for mail service to the residents of the park.
   (G)   Fire hydrants.
      (1)   When a manufactured home park is to be served by a central water system with lines of six inches or more in diameter, fire hydrants are to be installed every 1,000 feet, or no further than 500 feet from the furthest point of any lot within the manufactured home park. Where a public water line of six inches or more in diameter is available at the nearest state road to the manufactured home park, the developer shall use a water line of six inches or more in diameter within the park if a fire hydrant is required.
      (2)   In the event water lines within the manufactured home park are smaller than six inches in diameter, a fire hydrant shall be required at the entrance to the manufactured home park, if the public water supply line is six inches in diameter or greater.
      (3)   Fire hydrants shall be installed to the specification of the public water supply system serving the manufactured home park.
(Ord. passed 8-4-03)